Loading...
Product Overview
The dual power automatic switch is a newly deve loped miniature household power switch, which is mainly usedto test whether the main power supply or standby power supply is narmal. When the nomal power supply is abnormalthe standby power supply starts to work imme diately, which ensures the continuity, reliability and safety of powelsupply. This product is specially designed for household rail installation and is specially used for P230 distri bution b oxThe dual power automatic switch is suitable for emergency power supply systems with 50 or
60Hz and rated400V AC. ATS has the characteristics of solid structure, reliable conversian, convenient installation and maintenanceand long service life. t is widely used in various occasions where power failure cannot be sustained, and can beoperated by electricity or manually
ATS is composed of TSE and controller. According to GB/T14048.11, Part 6-1:multifunctional equipment and switchgear is formulated. it
can be seenthat ATS is the most qualified lowvaltage switchgear and control device.
Normal operation time and installation conditions
*Ambient ai"te rperat.re
The maximum temperare sr all nat exceed 40'0, the m nimum tamoerature srall not ke lower than-5'0, ancte average temperetre within 24hours shall not be nighertran 35 C.tAfit.de
The altiwde af the ir stallat on ste should not b:h gher than 2000m*Anosphrc condiicns
When the maximumm terrp?rature reaches 40℃, he relat ve huridily af the installajicr site shou d rot exezc509s when the temmpe "ature is the minin.n ter pcrawure.e C, the rclatve huridily is nigher for cxamnple, the.cm-perature is 25'0, and te relaive humidity is 90%6 Due to the temperature change spe ial measures should oe takento deal with +e c>cas onal concensaton or the surface of the procust.* Pclluicn g'ace
Tne pollution g'ade of ATS canforms ta grade 3 specifed in GE/T1404811* Installaton caregory
The installaicn type of ATS conicrs to the categpry specifed in GB/T 404811.tInstallatan codi0ns
A$ can be irstallec vertical yin cntrol cabinet or distihuion capinet Make s ure tre inszallation distance meetshe requcrents in Fiu 1.
Technical Parameter
|
Rated current le(A) |
16,20,25 |
32,40,50,63 |
80,100 |
|
Insulation voltage Ui |
AC690V,50Hz |
||
|
Rated voltage Ue |
AC400V,50Hz |
||
|
Classification |
PC级别:可以制造和承受,同时不产生短路电流PC class:can be manufactured and withstoodwithout short circuit current |
||
|
Utilization category |
AC-33iB |
AC-31B |
|
|
Pole No. |
2P |
3P |
4P |
|
Weight |
0.55 |
0.6 |
0.65 |
|
Rated short circuit current |
50kA |
||
|
Short circuit protection device(fuse) |
RT16-00-63A |
||
|
Rated impulse withstand voltage |
8kV |
||
|
Control circuit |
Rated control voltage Us:AC220V/50Hz Normal working conditions:85-110%Us |
||
|
Auxiliary circuit |
2 relays, each with two sets of contact convertercontact capacity:AC220V/50Hz le=5y |
||
|
Conversion time of contactor |
<50ms |
||
|
Operationconversiontime |
<50ms |
||
|
Returnconversiontime |
<50ms |
||
|
Powerofftime |
<50ms |
||